DESCRIPTION


Intelligent RAID Engine (ISET)

  • Convenient RAID application
    The RAID can be used immediately after being created. The system automatically initializes at the background.
  • Free from the impact of abnormal RAID status
    The performance of storage devices usually deteriorates in the case of RAID degradation. The Intelligent RAID Engine technology can be a shield against the impact of abnormal RAID status on services to ensure the normal operation of front-end monitoring services.
  • Free from the influence of concurrent reading/writing
    The IOPS multiplies when concurrent reading and writing occurs on a disk. The Intelligent RAID Engine technology can be a shield against the impact of video recording and playback to ensure the normal operation of front-end services.
  • Cache algorithms for videos
    Optimized read/write cache management algorithm, greatly improving access performance and extending the lifespan of HDDs.
  • SSD Cache
    The use of SSD Cache can be greatly improving access performance of hot data
  • Dynamic adjustment of reconstruction speed
    The system adjusts the reconstruction speed automatically based on the system conditions to reduce the impact of RAID reconstruction on services and to improve the effective utilization of system resources.

Super Error Correction (SEC)

  • Automatic disk inspection and repair
    The unique hard disk fault-tolerant processing algorithm ensures service continuity even when multiple disk errors exist in the array. Fault sectors can also be automatically repaired.
  • Fast disk reconstruction
    Data can be copied to a hot spare disk within a short period. This substantially reduces the read I/O of disk, speeds up the reconstruction, and avoids data loss.
  • RAID superblock backup
    Array composition is not affected when data in a certain sector cannot be read. In addition, damaged data can be repaired by using the backup sector to improve array reliability.

Data Protection

  • Data safe box
    Online embedded UPS protection and data safe box are provided to ensure secure writing of cache data into data safe box at unexpected power-off without data loss.
  • Disk pre-copying
    Pre-detection of failure is implemented to transfer data from risky disk to the hot spare disk.
  • Disk protection
    Once a disk error is detected, the disk repair process would automatically start. Data in the failed disk is recalculated from other disk in the array to remap the bad blocks of disk.
  • Link protection
  • Ink aggregation and dynamic failover ensure the read/write bandwidth without affecting the availability of data channels.

Three Dimensional Linear Expansion

  • Seamless expansion based on LUN resources
  • Multiple 48 Gbps Mini SAS HD interfaces for back-end expansion.

High-Quality Hardware Design

  • High density
    The innovative enclosure with 4U height that holds up to 48 disks, is space-saving
  • Carrier-class applications with high availability
    The application of Intel 64-bit server platform architecture, 64-bit multi-core processor, ECC DDR3 memory, and 64-bit storage OS ensure excellent service continuity by providing stable and reliable data access. The system availability reaches up to 99.999%.
  • Watchdog
    The system would be forced into the security mode in case of a failure. High-speed cache data is stored in the data safe box. Storage media in the data safe box can roam to the new system together with the array disk. The system can be recovered securely and conveniently.
  • Dual BIOS
    When the active BIOS fails to start, the system automatically detects the failure and switches to the standby BIOS. This ensures reliable system startup and BIOS update.
  • Redundant power supplies
    The hot-swappable power supply is designed in redundancy and load balancing mode. Automatic power switching in case of failure and online replacement of failed power supply are supported.
  • Overload protection
    The mechanism of hardware overload protection is provided. When the temperature reaches the protection threshold, the system automatically turns off to protect the disk data.
  • When CPU and memory malfunction or reach the protection threshold, the system automatically sends alarm messages through mails, short messages, and SNMP Trap.
  • Power protection
    Disk powered on sequentially during system startup, protection from impulse current.
  • Multistage fan speed and energy saving
    Fans with multistage speed are configured in the hot-swappable frame in redundancy mode. System power consumption can be balanced intelligently with heat dissipation calculation to ensure low power consumption and stable operation of the system.
  • Convenient maintenance
    Functions as indicator alarm, mail alarm, beep alarm, SNMP Trap alarm and SMS alarm are supported.
    Automatic startup after unexpected power-off, and timed startup and shutdown are also available.
    The environmental monitoring function allows the monitoring of the utilization of network interface and CPU, the querying of the access of LUN and RAID, as well as the management of device voltage and temperature. In this way, administrators can comprehensively inspect system operation condition and reasonably allocate resources to maximize the device performance.

Green Technology and Energy Conservation

  • Selected power supplies with high PF and conversion efficiency
  • Intel CPU with cutting-edge process technology and advanced architecture
  • Particularly selected chips with low power consumption for service model of video surveillance
  • Unique simplified design of board
    Reduced component type and quantity, under the affirmatory premise of the function, performance and reliability
  • Multistage fan speed
    Several temperature sensors are configured and built inside to intelligently control the fan speed.
  • Hibernation for unoccupied disks
  • Intelligent cache design
    Reasonably sort and buffer the read/write data by intelligent algorithm reduce the disk read/write times,and reduce the hard disk power consumption.

FUNCTIONS

 

High Performance

The application of latest hardware platform ensures a high video recording performance, up to 512ch/1024Mbps.

 

Modular Network Interface

Multiple interface module available, strong scalability of front-end service and back-end expansion.

 

Optimized Cache Algorithm

High bandwidth with write/read continuously

 

Cache Partition

Shared cache for each RAID and reserved cache for any RAID in need

 

Cache Reasonable Sorting

Change writing randomly into writing in sequence

 

Cache Pre-Read

Read from disk in advance according to video model

 

Redundant Modular Design

Replace failed modules with device online

 

Cable-Free Structure

Reliable electrical connections

 

Anti-Dust & Sulfide Alarm

Dust filter screen and sulfide alarm module at front panel

 

Anti-Vibration HDD Module

Aseismic design of hard disk bracket

 

Two Level of Remap

In addition to remap based on sector of hard disk, remap based on stripe is also available

 

 

S.M.A.R.T. Pre-Copy Tech

Copy data from risky disk to hot spare disk before disk failure according to S.M.A.R.T. information

 

No Sense Partial Rebuild

Only rebuild changed partial stripes when disk is pulled out by mistake and plugged back

 

Copy Rebuild

Rebuild data by rapid copy. The data that couldn’t be copied, will be rebuilt by XOR calculation

 

Cache Data Safe Box

Built-in battery module ensures write cache data rescued by data safe box when power off suddenly occurs

 

Fault Sector Repair

Fault sector can be repaired by XOR calculation automatically without service breakdown

 

Intelligent CPU

Intelligent frequency modulation CPU saves energy

 

Multistage Fan Speed

Several temperature sensors are inside to intelligently control the fan speed

SPECIFICATIONS

Storage controller Intel 64-bit multi-core processor
Memory 8 GB, up to 32 GB
Front-end Service Interface 3 10/100/1000 Mbps Ethernet interface
4 port 10/100/1000 Mbps Ethernet interface module(optional)
2 port 10 GE SFP+ interface module(optional)
4 port 10 GE SFP+ interface module(optional)
Back-end Expansion Interface 2x48 Gbps Mini SAS HD
Host Connection Up to 1024
HDD 24 SATA interfaces
Disk Capacity 1 TB, 2 TB, 3 TB, 4 TB , 5 TB, 6 TB, 8 TB
RAID JBOD and RAID 0,1,10, 5, 50,6
Dedicated hot-spare disk and global hot-spare disk
Maximum Number of Logic Resources 1024
Protocol Supported iSCSI
Alarm Feature Indicator alarm, beep alarm, mail alarm, SNMP Trap alarm, and short message alarm
Operating System Windows and Linux
Power Supply 1 default, 1 optional
Battery at least 1
Dimension (H ×W×D) Controller enclosure: 175.0mm×481.6mm×589.0mm
Power Consumption Controller enclosure :
< 450 W (fully configured)
Power Supply 100 V – 127 V/ 200 V – 240 V AC, 60 Hz/50 Hz
Weight Controller enclosure :
Fully configured:< 43 kg
Authentication certificate CE, FCC, TUV, UL, CCC
Operating temperature 5 °C~40°C / 41 °F ~ 104 °F,(10°C~ 35°C / 50 °F ~ 95°F Recommended)

Back to the top